Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins
Loading...
Files
Date
Journal Title
Journal ISSN
Volume Title
Publisher
University of Colombo
Abstract
Diabetes mellitus presents a profound global health crisis due to its chronic complications. At present, the Sri Lankan population has over 10% of diabetes, 11.5% of pre-diabetes prevalence, and overall dysglycaemia of around 21.8%. Hence, the detection of glycated proteins (GPs) in a fast way is vital for the prevention of diabetes and its complications. Despite the time-consuming techniques available worldwide for detecting GPs, this study presents a cost-effective, portable optical biosensor prototype that employs the fluorescence quenching behavior of graphene oxide (GO). The improved Hummers method was used to synthesize GO, and an in vitro BSA-glucose glycation model was established to prepare target protein concentrations ranging from 7.5 to 37.5 μL mL-1. XRD analysis was performed to confirm the structural properties of the synthesized GO. A 370 nm ultraviolet LED was used to excite the sample, and a 440 nm band-pass filter was used to detect the fluorescence emission, reaching the Hamamatsu S1223 light-to-voltage sensor. An ADC converter (ADS1256) with an accuracy of 24 bits was used to convert the electrical signal. The device cover was designed using SolidWorks and 3D printed. X-ray diffraction confirmed successful GO synthesis, with a characteristic peak at 2θ = 9.824°. Baseline system validation of the prototype device demonstrated structural stability, with a coefficient of variation of 0.18%. Calibration runs demonstrated a reliable concentration-dependent linear fluorescence detection, while the integrated GP-GO matrix validated a distinct fluorescence quenching effect ranging from 5.93% to 17.46%. Further, the prototype device exhibited a sensitivity of 0.67 mV (µL mL-1), revealing that the fluorescence quenching properties of the GO against GPs can be adopted for developing a cost-effective device in the detection of GPs.
Description
Keywords
Graphene Oxide, Glycated Proteins, Optical Biosensor, Fluorescence Quenching
Citation
Jayasekara, H., Bombugalage, B. L. S., Dhanuditha, L. D. S., Atapattu, H. Y. R., Abeysekera, W. K. S. M., & Jayanetti, J. K. D. S. (2026). Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins. Proceedings of the University of Colombo International Conference (UCIC) 2026, University of Colombo, Sri Lanka, p.30.
