Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins

dc.contributor.authorJayasekara, H.
dc.contributor.authorBombugalage, B. L. S.
dc.contributor.authorDhanuditha, L. D. S.
dc.contributor.authorAtapattu, H. Y. R.
dc.contributor.authorAbeysekera, W. K. S. M.
dc.contributor.authorJayanetti, J. K. D. S.
dc.date.accessioned2026-11-19T05:19:34Z
dc.date.issued2026
dc.description.abstractDiabetes mellitus presents a profound global health crisis due to its chronic complications. At present, the Sri Lankan population has over 10% of diabetes, 11.5% of pre-diabetes prevalence, and overall dysglycaemia of around 21.8%. Hence, the detection of glycated proteins (GPs) in a fast way is vital for the prevention of diabetes and its complications. Despite the time-consuming techniques available worldwide for detecting GPs, this study presents a cost-effective, portable optical biosensor prototype that employs the fluorescence quenching behavior of graphene oxide (GO). The improved Hummers method was used to synthesize GO, and an in vitro BSA-glucose glycation model was established to prepare target protein concentrations ranging from 7.5 to 37.5 μL mL-1. XRD analysis was performed to confirm the structural properties of the synthesized GO. A 370 nm ultraviolet LED was used to excite the sample, and a 440 nm band-pass filter was used to detect the fluorescence emission, reaching the Hamamatsu S1223 light-to-voltage sensor. An ADC converter (ADS1256) with an accuracy of 24 bits was used to convert the electrical signal. The device cover was designed using SolidWorks and 3D printed. X-ray diffraction confirmed successful GO synthesis, with a characteristic peak at 2θ = 9.824°. Baseline system validation of the prototype device demonstrated structural stability, with a coefficient of variation of 0.18%. Calibration runs demonstrated a reliable concentration-dependent linear fluorescence detection, while the integrated GP-GO matrix validated a distinct fluorescence quenching effect ranging from 5.93% to 17.46%. Further, the prototype device exhibited a sensitivity of 0.67 mV (µL mL-1), revealing that the fluorescence quenching properties of the GO against GPs can be adopted for developing a cost-effective device in the detection of GPs.
dc.identifier.citationJayasekara, H., Bombugalage, B. L. S., Dhanuditha, L. D. S., Atapattu, H. Y. R., Abeysekera, W. K. S. M., & Jayanetti, J. K. D. S. (2026). Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins. Proceedings of the University of Colombo International Conference (UCIC) 2026, University of Colombo, Sri Lanka, p.30.
dc.identifier.isbn978-624-5518-87-6
dc.identifier.urihttps://archive.cmb.ac.lk/handle/70130/9363
dc.language.isoen
dc.publisherUniversity of Colombo
dc.subjectGraphene Oxide
dc.subjectGlycated Proteins
dc.subjectOptical Biosensor
dc.subjectFluorescence Quenching
dc.titleGraphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
30.pdf
Size:
195.55 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: