Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins
| dc.contributor.author | Jayasekara, H. | |
| dc.contributor.author | Bombugalage, B. L. S. | |
| dc.contributor.author | Dhanuditha, L. D. S. | |
| dc.contributor.author | Atapattu, H. Y. R. | |
| dc.contributor.author | Abeysekera, W. K. S. M. | |
| dc.contributor.author | Jayanetti, J. K. D. S. | |
| dc.date.accessioned | 2026-11-19T05:19:34Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Diabetes mellitus presents a profound global health crisis due to its chronic complications. At present, the Sri Lankan population has over 10% of diabetes, 11.5% of pre-diabetes prevalence, and overall dysglycaemia of around 21.8%. Hence, the detection of glycated proteins (GPs) in a fast way is vital for the prevention of diabetes and its complications. Despite the time-consuming techniques available worldwide for detecting GPs, this study presents a cost-effective, portable optical biosensor prototype that employs the fluorescence quenching behavior of graphene oxide (GO). The improved Hummers method was used to synthesize GO, and an in vitro BSA-glucose glycation model was established to prepare target protein concentrations ranging from 7.5 to 37.5 μL mL-1. XRD analysis was performed to confirm the structural properties of the synthesized GO. A 370 nm ultraviolet LED was used to excite the sample, and a 440 nm band-pass filter was used to detect the fluorescence emission, reaching the Hamamatsu S1223 light-to-voltage sensor. An ADC converter (ADS1256) with an accuracy of 24 bits was used to convert the electrical signal. The device cover was designed using SolidWorks and 3D printed. X-ray diffraction confirmed successful GO synthesis, with a characteristic peak at 2θ = 9.824°. Baseline system validation of the prototype device demonstrated structural stability, with a coefficient of variation of 0.18%. Calibration runs demonstrated a reliable concentration-dependent linear fluorescence detection, while the integrated GP-GO matrix validated a distinct fluorescence quenching effect ranging from 5.93% to 17.46%. Further, the prototype device exhibited a sensitivity of 0.67 mV (µL mL-1), revealing that the fluorescence quenching properties of the GO against GPs can be adopted for developing a cost-effective device in the detection of GPs. | |
| dc.identifier.citation | Jayasekara, H., Bombugalage, B. L. S., Dhanuditha, L. D. S., Atapattu, H. Y. R., Abeysekera, W. K. S. M., & Jayanetti, J. K. D. S. (2026). Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins. Proceedings of the University of Colombo International Conference (UCIC) 2026, University of Colombo, Sri Lanka, p.30. | |
| dc.identifier.isbn | 978-624-5518-87-6 | |
| dc.identifier.uri | https://archive.cmb.ac.lk/handle/70130/9363 | |
| dc.language.iso | en | |
| dc.publisher | University of Colombo | |
| dc.subject | Graphene Oxide | |
| dc.subject | Glycated Proteins | |
| dc.subject | Optical Biosensor | |
| dc.subject | Fluorescence Quenching | |
| dc.title | Graphene Oxide Integrated Biosensing Platform for the Detection of In Vitro-Derived Glycated Proteins | |
| dc.type | Article |
