Facility reference level for common x-ray procedures: A preliminary study

Show simple item record

dc.contributor.author Satharasinghe, DM
dc.contributor.author Jeyasugiththan, J
dc.contributor.author Pallewatte, AS
dc.contributor.author Wanninayake, WMNMB
dc.date.accessioned 2021-09-04T07:11:05Z
dc.date.available 2021-09-04T07:11:05Z
dc.date.issued 2020
dc.identifier.uri http://archive.cmb.ac.lk:8080/xmlui/handle/70130/5896
dc.description.abstract Ionizing radiation is an essential tool in medical diagnosis and it brings great benefit to the patient. However, the associated risks due to the radiation are unavoidable. Therefore, close monitoring of radiation exposure should be performed in order to control the potential harm. As an advisory measure to improve optimization of patient’s radiation protection, Diagnostic Reference Levels (DRLs) was introduced by the International Commission on Radiation Protection (ICRP). The present study aims at the evaluation of the doses and their variation for selected x-ray procedures used by a single institution in Sri Lanka to determine a possible institutional DRL. The study included dose data and exposure parameters from 218 chest-Postero Anterior (PA), 33 abdomen-Antero Posterior (AP), 85 lumbar spine AP and 88 lumbar spine-Lateral (LAT) projections of patients (age between 19-78 years). The 3rd quartile dose values for the above projections were 16, 256, 155, 455 µGy. m2 respectively. Further, the above dose values were compared with international DRLs and we found that the lumbar spine lateral projection and abdomen AP are with higher dose levels. This preliminary study provides information on the selected study setting only however, can be used as a reference for quality improvement programs by others. en_US
dc.description.sponsorship Accelerating Higher Education Expansion and Development (AHEAD 6026-LK/8743-LK) en_US
dc.language.iso en en_US
dc.publisher Asia-Oceania Congress of Medical Physics (AOCMP) en_US
dc.relation.ispartofseries 20th AOCMP, 18th SEACOMP, Phuket, Thailand;
dc.subject institutional diagnostic reference level en_US
dc.subject IDRL en_US
dc.subject Diagnostic reference level en_US
dc.subject DRL en_US
dc.subject ionizing radiation en_US
dc.subject x-ray en_US
dc.title Facility reference level for common x-ray procedures: A preliminary study en_US
dc.type Article en_US