Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP)

Show simple item record

dc.contributor.author Ubhayawardana, D. L. N. L
dc.contributor.author Kottahachchi, J
dc.contributor.author Weerasekera, M. M
dc.contributor.author Wanigasooriya, I. W. M. P
dc.contributor.author Fernando, S. S. N
dc.contributor.author De Silva, M
dc.date.accessioned 2021-06-05T12:09:14Z
dc.date.available 2021-06-05T12:09:14Z
dc.date.issued 2013
dc.identifier.citation Ubhayawardana, D. L. N. L., Kottahachchi, J., Weerasekera, M. M., Wanigasooriya, I. W. M. P., Fernando, S. S. N., & De Silva, M. (2013). Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP). Endoscopy international open, 1(1), 12. en_US
dc.identifier.uri http://archive.cmb.ac.lk:8080/xmlui/handle/70130/5300
dc.description.abstract Background and study aim: Worldwide some endoscopyunitsroutinelycontinuetousemanual reprocessing techniques for disinfection of sideview endoscopes. The aim of this study was to evaluatetheoutcomequalityofmanualreprocessing techniques for removal and inactivation of the bioburden from side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP) in a tertiary referral endotherapy unit in Sri Lanka. Methods: 102 samples obtained from two different flexible side-view endoscopes (Olympus TJF Q 180V and Olympus TJF 160R) were tested for microbial growth. Three samples were collected each time; one swab from the tip before and another after manual reprocessing.The third sample was collected by flushing the working channel with sterile normal saline after manual reprocessing. Microorganisms were identified by culturing the samples. Result:: After reprocessing, culture-positive rates were 20% and 9% for the samples obtained from the tip and the working channel of the side-view endoscopes, respectively. Klebsiella spp.and Candida spp.werefoundtobethecommonest microorganisms in the samples from the tips and from the working channels, respectively, of the reprocessed side-viewendoscopes. Conclusion: There is a high culture-positive rate after reprocessing of the side-view endoscopes usingthemanualreprocessingprocedure,despite strict adherencetothe protocol for reprocessing. en_US
dc.language.iso en en_US
dc.subject Residual bioburden en_US
dc.subject Endoscopic Retrograde Cholangiopancreatography en_US
dc.title Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP) en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account