Please use this identifier to cite or link to this item: http://archive.cmb.ac.lk:8080/xmlui/handle/70130/6316
Title: Optimizing Image Noise as a means to improve Computed Tomography ATCM in Sri Lanka
Authors: Hishaam, H
Jeyasugiththan, Jeyasingam
Pallewatte, AS
Peterson, S
Keywords: Image Noise
Computed Tomography
ATCM
Issue Date: 2021
Publisher: The 21st Asia-Oceania Congress of Medical Physics (AOCMP -2021)
Series/Report no.: AOCMP - 2021;
Abstract: The use of automatic tube current modulation (ATCM) during CT scans has become widely popular over the past few years. This method significantly reduces patient dose by adapting the tube current during a CT scan to produce outputs with a specified target image quality throughout scans and across patients of varying sizes. Different scanners and ATCM programs modulate current using the following methods: angularly around the patient or based on an average attenuation along the z-axis; using a reference image and mA value or using provided noise reference levels. However, when misapplied, ATCM can subject a patient to excessive radiation doses or produce images of non- diagnostic quality. Thus, it is important to evaluate the impact different exposure parameters and other scan factors have on the image quality of CT scans across a patient population. This work evaluates image noise levels, a vital factor in judging image quality, of CT scans using ATCM taken at hospitals across Sri Lanka. Considering the default tube voltage of 120 kVp for chest and abdomen CT scans in Sri Lanka, except in very rare exceptions, a review of international papers studying various CT scan factors is included. These factors include exposure parameters such as tube potential (kVp), and pitch value, as well as patient centering. Using this evaluation of image noise levels, this work aims to establish a CT scan ATCM protocol for hospitals across Sri Lanka. International studies are used as context to establish this protocol that is highly specific to Sri Lankan patients while also considering the fact that higher noise values are tolerable for larger patients due to fat levels providing greater image contrast. The protocol will establish the CT scan factors that optimize image noise levels when ATCM is used on Sri Lankan patients.
URI: http://archive.cmb.ac.lk:8080/xmlui/handle/70130/6316
Appears in Collections:Department of Nuclear Science

Files in This Item:
File Description SizeFormat 
Ueshell AOCMP 2021.pdf1.8 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.